Marshall Thermoking Logo
Company Info News Jobs
Equipment Covered Live Job Tracking System Service Planning
Full Repair & Maintenance Fleet Management
Trailer Truck Small Truck Accessories Parts Recycling Solutions
Find Us Depots Enquiries Form Links

V300
 Superior Temperature Control:
  • High airflow to provide superior temperature management leading to a more uniform temperature distribution thereby protecting perishable goods during transport
  • Higher cooling capacity at all temperatures especially on electric standby operation for
    • Faster temperature recovery from multiple door openings during distribution operations
    • Quicker pre-cooling on electric operation
 Improved Reliability of Electrical Components:
  • Introduction of new long life fans in both the condenser and evaporator with a working life 3 times longer than previously
  • IP55 easily accessible electric box and new sealed connectors
  • Components requiring frequent service such as fuses, fan and fan filter are easily accessible without affecting the seal of the electrical control box
  • Individual fuses and relays for independent protection of the loads
  • Hermetic transformer and connecting wires
  • Large, compact filtering capacitors for improved d.c. supply stability during standby operation
  • The new Direct Smart Reefer has several features to protect and increase the life of the components
    • vehicle battery protection: low battery voltage check, sequential evaporator start, unit delays start during vehicle start-up, isolation of power sources by relays
    • time limit between turning off and on the unit to extend life of electrical components and compressor
    • clutch delay timer extends electrical motor life
 Ease of Maintenance and Service:
  • The new DSR has a
    • Maintenance reminder
    • Easy to understand alarm codes for quick diagnostics
  • The condenser cover can now be removed and the unit will continue to safely function for easy diagnostics
 Ease of Installation:
  • Added lifting eyes to the larger platform
    • Accessible mounting holes
    • Fittings outside of the evaporator to reduce installation time and guarantee airflow
 New User-Friendly Direct Smart Reefer With the Following Benefits:
  • Continuous temperature monitoring
  • Three standard hourmeters - to record working hours
  • Manual or automatic defrost
  • In cab box may be removed after presetting conditions
 Data Capture and Management Solutions:
  • The new V-Series offers the possibility to work with:
    • DAS (Data Acquisition System) - records temperatures. The DAS is compatible with Wintrac, a windows based management software package designed to communicate, download and display the information from Thermo King temperature recorders. It can be connected with R:COM for remote temperature downloading and monitoring.
    • R:COM - remotes wireless communication of data logged by data recorder. The downloaded data is collected by a PC where it is viewed using Wintrac.
 Refrigeration Capacity: U.S. Standard - System net cooling capacity at 100 degrees F (38 degrees C) ambient and 2400 compressor rpm.
  Air Return On the Road Electric Stand-by 50Hz
Degrees F Degrees C Btu/hr Watts Btu/hr Watts
35 2 7,720 2,260 5,000 1,465
0 -18 3,880 1,135 2,320 680
 Refrigeration Capacity: European Standard - System net cooling capacity under ATP conditions including 30 degrees C (86 degrees F) ambient.
  Air Return On the Road Electric Stand-by 50Hz
Degrees C Degrees F Watts Btu/hr Watts Btu/hr
0 32 2,865 9,789 1,885 6,335
-20 -4 1,200 4,100 720 2,460
 Refrigerant:
  • HFC R-134a (1.75 kg)
  • Chlorine: Zero
 Defrost:
  • Automatic hot gas defrost
 Compressor (Engine Driven):
  • Number of cylinders: 6
  • Displacement: 146.7 cm³ (8.95 cu in)
  • Speed Max recommended: 3,000 rpm
  • Jet Lube™ compressor lubrication and cooling systems
 Evaporator Blower Performance:
  • Airflow volume: 1295 m³/h (760 cu. ft/min)
 Electric Motors:
  • dc voltage options: 12Vdc and 24Vdc
  • Total current consumption on the road: 12Vdc - 28A    24Vdc - 15A
  • Total stand-by current consumption:
    • 230V/1 Phase/50 Hz    10A
    • 230V/1 Phase/60 Hz    10.2A
    • 115V/1 Phase/60 Hz    16A
    • 400V/3 Phase/50 Hz    4.5A
    • 230V/3 Phase/50 Hz    7.7A
    • 230V/3 Phase/60 Hz    7.9A
 System Components:
  • Small condenser section: V-300 series without electric stand-by
  • Large condenser section: V-300 series with electric stand-by
  • Ultra slim evaporator ES300
  • Engine driven compressor
  • Installation kit
  • In-cab Direct Smart Reefer
  • Vehicle drive kit (on request)
 Weight: (approximate) lbs kg
Condenser w/o electric stand-by 111 50
Condenser with electric stand-by 165 75
ES300 (Ultra Slim Evaporator) 40 18
Installation Kit (incl. cpr.) 62 28
 Dimensions: Height Width Depth
Condenser w/o electric stand-by 7.9 in 200 mm 31.1 in 789 mm 19.7 in 500 mm
Condenser with electric stand-by 7.9 in 200 mm 46.5 in 1180 mm 19.1 in 485 mm
ES300 (Ultra Slim Evaporator) 7.0 in 178 mm 38.8 in 985 mm 21.7 in 550 mm
In-cab Direct Smart Reefer 1.8 in 46 mm 5.3 in 135 mm 1.0 in 25 mm
 

Total Kare
EMI 3000
30% More Efficient
2 Year Warrenty

 

MTK Side Panel
Copyright © Marshall Thermoking