- Model
30: Cooling and heating
on engine operation.
- Model
50: Cooling and heating
on engine and electric stnadby
operation.
|
| Refrigeration
Capacity: System
net cooling capacity at 30 degrees
C ambient temperature under ATP
conditions. |
| Return
Air To Evaporator |
0
Degrees C |
-20
Degrees C |
| Capacity
on engine power |
9,200
Watts |
5,800
Watts |
| Capacity
on electric stand-by |
7,400
Watts |
5,300
Watts |
|
| Refrigerant: |
- R-404A
zero Ozone Depletion Potential
(ODP)
- Internationally
approved
- Charge:
5.0 kg
|
| Engine: |
- TK482
direct-injection diesel engine
- Four-cylinder,
liquid cooled
- Rating:
18.3 kW
- Maintenance
interval: 3000 hrs
|
| Compressor: |
- Lightweight
aluminum alloy
- Four-cylinder
with by-pass oil filter
- Model
X426
- Displacement:
423 cc
|
| Airflow: on high speed engine operation |
- Airflow
volume at 0 Pa static pressure:
4250 m³/hr
- Airflow
volume at 450 Pa static pressure:
3150 m³/hr
- Discharge
velocity (airthrow): 12 m/sec
|
|
| Weight:
(approximate) |
kg |
| Model
30 |
733 |
| Model
50 |
844 |
| Dimensions: |
Height |
Width |
Depth |
| Condenser |
2235
mm |
2056
mm |
430
mm |
| Evaporator |
1160
mm |
1676
mm |
102